← All Advisories
Reported from OT-Advisories.com as of

Mendix Studio Pro's MCP Server Binds Its HTTP Interface Without Restricting the Address, Scoring 8.8

Last refreshed2026-11-17

Status: UPDATED  |  Advisory ID: CVE-2026-112136

Key Details

CVECVE-2026-112136
CVSS Score / Version
8.8 (High) / CVSS v3.1
Updated2026-11-10
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is network; attack complexity is low; privileges required is none; user interaction is required; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Siemens Mendix Studio Pro 11 and Siemens Mendix Studio Pro 11.12
Classified as
CWE-1327 (Binding to an Unrestricted IP Address)
Exploitation prediction (EPSS)
0.30% probability of exploitation in the next 30 days (24% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
SiemensMendix Studio Pro 11
SiemensMendix Studio Pro 11.12
SubsystemsGeneral OT
SectorsMultiple

What to Know

A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely. (NVD)

What to Do

Mendix Studio Pro 11: All versions >= V11.15.0 < V11.16.0 affected by all CVEs CVE-2026-112136 CVE-2026-112137. Update to V11.16.0 or later version (https://docs.mendix.com/releasenotes/studio-pro/11/). Mendix Studio Pro 11.12: All versions >= V11.12.6 < V11.12.7 affected. Update to V11.12.7 or later version (https://docs.mendix.com/releasenotes/studio-pro/11.12/). Mitigation for CVE-2026-112136: Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.
Source: Siemens SSA-710379

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-112136
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-112136
Vendor advisoryhttps://cert-portal.siemens.com/productcert/html/ssa-710379.html
Report compilation © 2026 OT-Advisories.com  ·  CC BY 4.0  ·  Source materials remain the property of their respective publishers as cited.