Status: UPDATED | Advisory ID: CVE-2026-23456
| CVE | CVE-2026-23456 |
| CVSS Score / Version | |
| Updated | 2026-11-10 |
| CVSS Vector | |
| CVSS Prose | |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Linux | Linux Kernel | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) |
| Subsystems | Controllers & Field I/O, OT Supporting Infrastructure |
| Sectors | All Sectors |
In the Linux kernel, the following vulnerability has been resolved:
netfilter: nf_conntrack_h323: fix OOB read in decode_int() CONS case
In decode_int(), the CONS case calls get_bits(bs, 2) to read a length
value, then calls get_uint(bs, len) without checking that len bytes
remain in the buffer. The existing boundary check only validates the
2 bits for get_bits(), not the subsequent 1-4 bytes that get_uint()
reads. This allows a malformed H.323/RAS packet to cause a 1-4 byte
slab-out-of-bounds read.
Add a boundary check for len bytes after get_bits() and before
get_uint(). (NVD)
Currently no fix is available. Siemens has identified the following specific mitigations that customers can apply to reduce the risk: Only build and run applications from trusted sources. Limit access to the interactive shell of the additional GNU/Linux subsystem to trusted personnel only.
Source: Siemens SSA-0825562 other advisories state the same guidance
Source: Siemens SSA-019113
Source: Siemens SSA-457936