Siemens SINEC NMS Password Reset Request Authorization Not Validated, Allowing Authenticated User to Reset Any Account Password
Last refreshed2026-11-16
Status: UPDATED
| Advisory ID: CVE-2026-25654
Key Details
CVE
CVE-2026-25654
CVSS Score / Version
8.8 (High) / CVSS v3.1
Updated
2026-06-17
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is network; attack complexity is low; privileges required is low; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Siemens SINEC NMS
Classified as
CWE-639 (Authorization Bypass Through User-Controlled Key)
Exploitation prediction (EPSS)
0.46% probability of exploitation in the next 30 days (41% percentile) -- FIRST.org's EPSS model.
Affected Products, Subsystems & Sectors
Vendor
Product
Affected Versions
Patch Status
Siemens
SINEC NMS
Subsystems
Engineering & OT Operations Software
Sectors
Multiple
What to Know
A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3). Affected products do not properly validate user authorization when processing password reset requests. This could allow an authenticated remote attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. (NVD)
What to Do
Vulnerability CVE-2026-25654: Affected products do not properly validate user authorization when processing password reset requests, allowing an authenticated remote attacker to bypass authorization checks and reset the password of any arbitrary user account. SINEC NMS All versions < V4.0 SP3 affected by CVE-2026-25654. Update to V4.0 SP3 or later version: https://support.industry.siemens.com/cs/ww/en/view/110000760/. Mitigations: Limit network access to trusted users and systems only. Source: Siemens SSA-605717