← All Advisories
Reported from OT-Advisories.com as of

Linux Linux Kernel Buffer Overflow Rated 8.8 CVSS

Last refreshed2026-11-16

Status: UPDATED  |  Advisory ID: CVE-2026-31622

Key Details

CVECVE-2026-31622
CVSS Score / Version
8.8 (High) / CVSS v3.1
Updated2026-10-15
CVSS Vector
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is adjacent; attack complexity is low; privileges required is none; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Linux Kernel and Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem
Classified as
CWE-120 (Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'))
Exploitation prediction (EPSS)
0.29% probability of exploitation in the next 30 days (22% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
LinuxLinux Kernel
SiemensSIMATIC S7-1500 TM MFP - GNU/Linux subsystem
SubsystemsControllers & Field I/O, OT Supporting Infrastructure
SectorsAll Sectors

What to Know

In the Linux kernel, the following vulnerability has been resolved:

NFC: digital: Bounds check NFC-A cascade depth in SDD response handler

The NFC-A anti-collision cascade in digital_in_recv_sdd_res() appends 3

or 4 bytes to target->nfcid1 on each round, but the number of cascade

rounds is controlled entirely by the peer device. The peer sets the

cascade tag in the SDD_RES (deciding 3 vs 4 bytes) and the

cascade-incomplete bit in the SEL_RES (deciding whether another round

follows).

ISO 14443-3 limits NFC-A to three cascade levels and target->nfcid1 is

sized accordingly (NFC_NFCID1_MAXSIZE = 10), but nothing in the driver

actually enforces this. This means a malicious peer can keep the

cascade running, writing past the heap-allocated nfc_target with each

round.

Fix this by rejecting the response when the accumulated UID would exceed

the buffer.

Commit e329e71013c9 ("NFC: nci: Bounds check struct nfc_target arrays")

fixed similar missing checks against the same field on the NCI path. (NVD)

What to Do

Currently no fix is available
Source: Siemens SSA-784472