attack vector is network; attack complexity is low; privileges required is low; user interaction is none; scope is unchanged; confidentiality impact is none; integrity impact is high; availability impact is high.
Affected products
Nozomi Networks Guardian, Nozomi Networks CMC, and Siemens RUGGEDCOM APE1808
Classified as
CWE-266 (Incorrect Privilege Assignment)
Exploitation prediction (EPSS)
0.40% probability of exploitation in the next 30 days (35% percentile) -- FIRST.org's EPSS model.
Affected Products, Subsystems & Sectors
Vendor
Product
Affected Versions
Patch Status
Nozomi Networks
Guardian
Nozomi Networks
CMC
Siemens
RUGGEDCOM APE1808
Subsystems
Industrial Networking & Connectivity
Sectors
Multiple
What to Know
An Incorrect Privilege Assignment vulnerability was discovered in the synchronization functionality due to Arc sensors receiving CLI permissions. An authenticated user with limited privileges can push administrative CLI commands through the sync, altering the device configuration, and/or affecting its availability. (NVD)
What to Do
Workarounds and Mitigations: Review all enabled sensors and disallow or delete untrusted ones. Solutions: Upgrade to v26.2.0 or later. Source: Nozomi Networks NN-2026:13-01