Status: UPDATED | Advisory ID: CVE-2026-33892
| CVE | CVE-2026-33892 |
| CVSS Score / Version | |
| Updated | 2026-06-17 |
| CVSS Vector | |
| CVSS Prose | |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Siemens | Industrial Edge Management Pro V1 | ||
| Siemens | Industrial Edge Management Pro V2 | ||
| Siemens | Industrial Edge Management Virtual |
| Subsystems | Industrial Edge, IIoT & Cloud Integration |
| Sectors | Multiple |
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.
This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.
Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.
Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected. (NVD)
Industrial Edge Management Pro V1 All versions >= V1.7.6 < V1.15.17 affected by CVE-2026-33892 Update to V1.15.17 or later version. Industrial Edge Management Pro V2 All versions >= V2.0.0 < V2.1.1 affected by CVE-2026-33892 Update to V2.1.1 or later version. Industrial Edge Management Virtual All versions >= V2.2.0 < V2.8.0 affected by CVE-2026-33892 Update to V2.8.0 or later version
Source: Siemens SSA-609469
| Source | Reference |
|---|---|
| NVD | https://nvd.nist.gov/vuln/detail/CVE-2026-33892 |
| CVE | https://www.cve.org/CVERecord?id=CVE-2026-33892 |
| Vendor advisory | https://cert-portal.siemens.com/productcert/html/ssa-609469.html |