Nozomi Guardian and CMC Update Bundles Allow Two OS Command Injections by Administrators
Last refreshed2026-11-16
Status: UPDATED
| Advisory ID: CVE-2026-33924
Key Details
CVE
CVE-2026-33924
CVSS Score / Version
7.2 (High) / CVSS v3.1
Updated
2026-10-29
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is network; attack complexity is low; privileges required is high; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Nozomi Networks Guardian and Nozomi Networks CMC
Classified as
CWE-78 (Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'))
Exploitation prediction (EPSS)
1.11% probability of exploitation in the next 30 days (67% percentile) -- FIRST.org's EPSS model.
Affected Products, Subsystems & Sectors
Vendor
Product
Affected Versions
Patch Status
Nozomi Networks
Guardian
Nozomi Networks
CMC
Subsystems
Industrial Networking & Connectivity
Sectors
Multiple
What to Know
Two OS command injection vulnerabilities were discovered in the update installation functionality due to insufficient validation of the update bundle contents. An attacker with administrative privileges can remotely supply a crafted update bundle that, when installed, causes arbitrary commands to be executed with root privileges, allowing the attacker to read or modify sensitive data, change the appliance configuration, or shut down the appliance. (NVD)
What to Do
Monitor Nozomi Networks's web page for any future patch releases.