← All Advisories
Reported from OT-Advisories.com as of

MB Connect Line mbNET/mbNET.rokey High-Privilege Config Generator OS Command Injection via Unsanitized Config Value

Last refreshed2026-11-19

Status: UPDATED  |  Advisory ID: CVE-2026-40852

Key Details

CVECVE-2026-40852
CVSS Score / Version
7.2 (High) / CVSS v3.1
Updated2026-06-17
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is network; attack complexity is low; privileges required is high; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
MB connect line mbNET/mbNET.rokey, MB connect line mbNET.mini, Helmholz REX200/250, and Helmholz REX100
Classified as
CWE-78 (Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'))
Exploitation prediction (EPSS)
0.37% probability of exploitation in the next 30 days (32% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
MB connect linembNET/mbNET.rokey
MB connect linembNET.mini
HelmholzREX200/250
HelmholzREX100
SubsystemsGeneral OT
SectorsMultiple

What to Know

A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability. (NVD)

What to Do

Update: mbNET/mbNET.rokey: 8.4.5 mbNET.mini: 3.0.3
Source: MB connect line GmbH VDE-2026-054

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-40852
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-40852
Vendor advisoryhttps://www.certvde.com/en/advisories/VDE-2026-054/
Report compilation © 2026 OT-Advisories.com  ·  CC BY 4.0  ·  Source materials remain the property of their respective publishers as cited.