Status: UPDATED | Advisory ID: CVE-2026-52933
| CVE | CVE-2026-52933 |
| CVSS Score / Version | |
| Updated | 2026-11-10 |
| CVSS Vector | |
| CVSS Prose | |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Linux | Linux Kernel | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) |
| Subsystems | Controllers & Field I/O, OT Supporting Infrastructure |
| Sectors | All Sectors |
In the Linux kernel, the following vulnerability has been resolved:
io_uring/poll: fix signed comparison in io_poll_get_ownership()
io_poll_get_ownership() uses a signed comparison to check whether
poll_refs has reached the threshold for the slowpath:
if (unlikely(atomic_read(&req->poll_refs) >= IO_POLL_REF_BIAS))
atomic_read() returns int (signed). When IO_POLL_CANCEL_FLAG
(BIT(31)) is set in poll_refs, the value becomes negative in
signed arithmetic, so the >= 128 comparison always evaluates to
false and the slowpath is never taken.
Fix this by casting the atomic_read() result to unsigned int
before the comparison, so that the cancel flag is treated as a
large positive value and correctly triggers the slowpath. (NVD)
Currently no fix is available. Siemens has identified the following specific mitigations that customers can apply to reduce the risk: Limit access to the interactive shell of the additional GNU/Linux subsystem to trusted personnel only. Only build and run applications from trusted sources.
Source: Siemens SSA-4579361 other advisory states the same guidance
Source: Siemens SSA-019113