← All Advisories
Reported from OT-Advisories.com as of

Siemens SIMATIC IoT2050 Advanced with Node-RED Does Not Enforce Authentication on Node-RED API Endpoint

Last refreshed2026-11-16

Status: UPDATED  |  Advisory ID: CVE-2026-58115

Key Details

CVECVE-2026-58115
CVSS Score / Version
10.0 (Critical) / CVSS v3.1
Updated2026-11-04
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS Prose
attack vector is network; attack complexity is low; privileges required is none; user interaction is none; scope is changed; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Siemens SIMATIC IoT2050 Advanced, Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2), Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2), Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2), and Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)
Classified as
CWE-306 (Missing Authentication for Critical Function)
Exploitation prediction (EPSS)
0.89% probability of exploitation in the next 30 days (60% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
SiemensSIMATIC IoT2050 Advanced
SiemensSIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)
SiemensSIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)
SiemensSIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)
SiemensSIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)
SubsystemsGeneral OT
SectorsMultiple

What to Know

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.

This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges. (NVD)

What to Do

SIMATIC IoT2050 family (Advanced/Basic/M.2/SM): All versions < V4.3.4-1 running Industrial OS with Node-RED installed affected by CVE-2026-58115 Update to V4.3.4-1 or later version. All versions running Example Image versions with Node-RED installed affected by CVE-2026-58115 Currently no fix is available (consistent across all four IoT2050 device models)
Source: Siemens SSA-834709

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-58115
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-58115
Vendor advisoryhttps://cert-portal.siemens.com/productcert/html/ssa-834709.html
Report compilation © 2026 OT-Advisories.com  ·  CC BY 4.0  ·  Source materials remain the property of their respective publishers as cited.