Siemens SIMATIC IPC Products Include a BIOS Vendor Test Key in the UEFI Secure Boot Database, Allowing Locally Privileged Attackers to Boot Unsigned Software
Last refreshed2026-11-16
Status: UPDATED
| Advisory ID: CVE-2026-72895
Key Details
CVE
CVE-2026-72895
CVSS Score / Version
7.7 (High) / CVSS v3.1
Updated
2026-10-13
CVSS Vector
CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
CVSS Prose
attack vector is local; attack complexity is high; privileges required is none; user interaction is required; scope is changed; confidentiality impact is high; integrity impact is high; availability impact is high.
A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device. (NVD)
What to Do
SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G: All versions < V28.01.15 affected by CVE-2026-72895, update to V28.01.15 or later version. SIMATIC IPC BX-21A: update to V31.01.13 or later version. SIMATIC IPC RW-543A: update to V1.1.4 or later version. https://support.industry.siemens.com/cs/ww/en/view/109763408/ Note: After upgrading to the fixed BIOS version, users must load the BIOS default settings. If Secure Boot keys were already provisioned, they must be provisioned again afterwards. Source: Siemens SSA-159454