Reusing a Python BZ2Decompressor After a Caught Decompression Error Resumes From Invalid State and Writes Past a Stack Buffer on Untrusted Input

Last refreshed2026-11-16

Status: UPDATED  |  Advisory ID: CVE-2026-9669

Key Details

CVECVE-2026-9669
CVSS Score / Version
8.2 (High) / CVSS v4.0
Updated2026-11-10
Affected products
see table below
Classified as
CWE-121 (Stack-based Buffer Overflow)
Exploitation prediction (EPSS)
0.43% probability of exploitation in the next 30 days (38% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
Python Software FoundationCPython
SiemensSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)
SiemensSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)
SiemensSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)
SiemensSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)
SiemensSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)
SubsystemsControllers & Field I/O
SectorsMultiple

What to Know

bz2.BZ2Decompressor objects could be reused after a decompression error. If an application caught the resulting OSError and retried with the same decompressor, crafted input could cause the decompressor to resume from an invalid internal state and perform out-of-bounds writes to a stack buffer. This could crash the process when processing untrusted data. (NVD)

What to Do

Currently no fix is available. See further recommendations from section Mitigations.
Source: Siemens SSA-457936